Siemens 3VA1225-5FF42-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-5FF42-0BH0 SENTRON MCCB, 125 A, 4-Pole, 187

MPN3VA1225-5FF42-0BH0

Siemens SENTRON 3VA1225-5FF42-0BH0, molded case circuit breaker, 4-pole, 125 A, breaking capacity 187 kA at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1225-5FF42-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12255FF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1225-5FF42-0BH0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.59.5 W

Protection & Trip Unit

3VA1225-5FF42-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1225-5FF42-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1225-5FF42-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1225-5FF42-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1225-5FF42-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1225-5FF42-0BH0 is a 4-pole molded case circuit breaker (MCCB) rated for a continuous current of 125 A, with an insulation voltage of 800 V. It is designed for line protection — the primary role is as a main or feeder breaker in a distribution panel, not a motor-protective device. The 125 A rating is fixed; there is no adjustable thermal or magnetic trip block on this variant, so the breaker is sized for a specific load and cannot be field-reconfigured for a lower ampacity.

Breaking capacity across the voltage range

This MCCB delivers 187 kA interrupting capacity at 240 V AC, dropping to 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. These are high-interrupting ratings for a 125 A frame — useful where fault current is high (close to a transformer) and you need selectivity without stepping up to a larger breaker. The 690 V figure (17 kA) is the weakest point: if your system runs at 690 V and available fault current exceeds that, this breaker won't hold. Check the point-of-common-coupling SCCR before specifying.

Thermal derating

Rated 250 A at 40, 45, and 50 °C ambient — that's the continuous current the breaker's thermal-magnetic trip can carry without nuisance tripping. At 55 °C it derates to 243 A, at 60 °C to 237 A, at 65 °C to 230 A, and at 70 °C to 223 A. Operating range is -25 to +70 °C; storage range is -40 to +80 °C. If the panel ambient runs above 50 °C, the derated numbers govern — don't load the breaker to 125 A if the enclosure hits 70 °C.

Built-in auxiliaries and releases

Factory-fitted with an undervoltage release (UVR) and a complement of two auxiliary switches plus one trip alarm switch (HQ). The UVR means the breaker drops out if control voltage is lost — typical for emergency-stop or undervoltage protection schemes. The auxiliary switches provide status feedback (open/closed) and the trip alarm signals a fault condition separately. No communication function on this variant; no ground-fault monitoring.

Physical fit and panel integration

Dimensions: 70 mm deep, 140 mm wide, 158 mm high. This is a standard SENTRON 3VA frame size for a 125 A 4-pole — it mounts on a DIN rail or can be screw-fixed to a backplate. The 140 mm width is the key fit dimension: if your panel was laid out for a narrower 3-pole breaker, this 4-pole won't fit without a wider slot. The trip indicator (mechanical flag) is visible through the front cover, so you can see a trip at a glance without opening the door.

Frequently asked questions

What is the breaking capacity of 3VA1225-5FF42-0BH0 at 415 V?

The breaking capacity is 121 kA at 415 V AC. At 240 V it is 187 kA, at 440 V it is 75.6 kA, at 500 V it is 30 kA, and at 690 V it is 17 kA.

Does this MCCB include an undervoltage release?

Yes, it is factory-fitted with an undervoltage release (UVR), plus two auxiliary switches and one trip alarm switch (HQ).