Siemens 3VA1225-5FF42-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-5FF42-0DA0 SENTRON MCCB, 250 A, 4-Pole, Line

MPN3VA1225-5FF42-0DA0

Siemens SENTRON 3VA1225-5FF42-0DA0, molded case circuit breaker, 4-pole, line protection, rated current 250 A, breaking capacity 187 kA at 240 V, 121 kA at 415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1225-5FF42-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1225-5FF42-0DA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243.3 A
Current at 60 °C236.5 A
Current at 65 °C229 A
Current at 70 °C223 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V36 kA
Breaking capacity at 690 V17 kA

Protection & Trip Unit

3VA1225-5FF42-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1225-5FF42-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1225-5FF42-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1225-5FF42-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1225-5FF42-0DA0 — Mechanical
ParameterValue
Height158 mm
Width140 mm
Depth70 mm

Product details

What this MCCB carries

The Siemens SENTRON 3VA1225-5FF42-0DA0 is a 4-pole molded case circuit breaker rated for 250 A continuous current at 40 °C. It holds that rating flat through 50 °C — at 55 °C it derates to 243.3 A, and at 70 °C it's still good for 223 A. That thermal curve means you don't lose headroom until the panel ambient pushes past 50 °C. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 36 kA at 440 V, and 17 kA at 690 V. That 187 kA figure at 240 V covers high-fault utility feeds; the 121 kA at 415 V handles most industrial distribution downstream of a transformer. The overcurrent release is a TM240 thermal-magnetic type. An undervoltage release (UVR) is fitted as standard — part number 3VA9608-0BB25 for the integrated auxiliary trip. No auxiliary contact block is included; that's a separate add-on if you need remote status.

Footprint and panel fit

Dimensions are 158 mm high, 140 mm wide, 70 mm deep. That 140 mm width is a 4-pole frame — it'll take up four module spaces on a DIN rail if you're using a mounting plate adapter. The IP40 front protection means it's fine inside a closed panel; no washdown rating. N-conductor protection is set at 50% of the phase rating. No phase-failure detection, no ground-fault monitoring, no communication module — this is a straight line-protection breaker with a UVR trip coil.

Frequently asked questions

What does the TM240 overcurrent release mean?

TM240 is a thermal-magnetic release with a fixed thermal pickup of 250 A (the rated continuous current). The magnetic trip threshold is set at 240 A times the multiplier — it's a standard line-protection curve for feeder and main breaker applications.

Does this breaker include an undervoltage release?

Yes, an undervoltage release (UVR) is fitted. The integrated auxiliary trip part number for the UVR is 3VA9608-0BB25.