Skip to main content
Siemens 3VA1225-6EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-6EF32-0CC0 SENTRON MCCB, 250 A, 220 kA at 24

MPN3VA1225-6EF32-0CC0

Siemens SENTRON molded case circuit breaker, 3VA1225-6EF32-0CC0, 3-pole, line protection, 250 A rated at 40-50 °C, 220 kA interrupting at 240 V, with undervoltage release and 2 HQ auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1225-6EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12256EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1225-6EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.59.5 W

Protection & Trip Unit

3VA1225-6EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1225-6EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1225-6EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1225-6EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1225-6EF32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1225-6EF32-0CC0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection, carrying a continuous current rating of 250 A across the 40 °C to 50 °C band without derating, then stepping down to 223 A at 70 °C. Its interrupting capacity reaches 220 kA at 240 V, 154 kA at 415 V, and 75.6 kA at 440 V, which makes it suitable for high-fault-current main feeders or large sub-distribution boards where fault levels exceed standard MCCB ratings. The breaker includes an undervoltage release (UVR) and two HQ auxiliary switches, so it can integrate into safety-related undervoltage trip schemes and provide remote status feedback without external add-on modules.

Integration and footprint

Dimensions are 158 mm high, 105 mm wide, and 70 mm deep — a standard SENTRON 3VA frame size that fits common panel cutouts and busbar systems. Rated insulation voltage is 800 V.

MPN
3VA1225-6EF32-0CC0