Skip to main content
Siemens 3VA1225-6EF42-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-6EF42-0HC0 SENTRON MCCB, 250 A, 4-Pole, 220

MPN3VA1225-6EF42-0HC0

Siemens SENTRON 3VA1225-6EF42-0HC0, molded case circuit breaker, 4-pole, 250 A at 40 °C, breaking capacity 220 kA at 240 V, line protection, shunt trip release, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1225-6EF42-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12256EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1225-6EF42-0HC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.57 W

Protection & Trip Unit

3VA1225-6EF42-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1225-6EF42-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1225-6EF42-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1225-6EF42-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1225-6EF42-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

What this MCCB delivers on the line side

The Siemens SENTRON 3VA1225-6EF42-0HC0 is a 4-pole molded case circuit breaker rated 250 A at 40 °C, sized for line protection in distribution panels. Its interrupting capacity hits 220 kA at 240 V AC and 154 kA at 415 V AC — figures that cover high-fault utility feeds and transformer secondaries without cascading upstream. The 800 V rated insulation voltage gives headroom for 690 V industrial networks.

Breaking capacity across voltages — what it means for your SCCR

This MCCB delivers 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. For a 480 V panel, the 75.6 kA rating at 440 V is the closest published figure; the 30 kA at 500 V covers 480 V systems with margin. The 17 kA at 690 V suits European 690 V motor control centers. These values define the available fault current the breaker can safely interrupt — critical for SCCR compliance under UL 508A or IEC 61439.

Thermal derating and continuous current

Rated 250 A continuously at 40 °C, 45 °C, and 50 °C. Derating starts at 55 °C: 243 A, then 237 A at 60 °C, 230 A at 65 °C, and 223 A at 70 °C. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Maximum power loss is 57 W. The 4-pole frame fits a 140 mm wide × 158 mm high × 70 mm deep footprint — standard for SENTRON 3VA plug-in or fixed mounting.

Auxiliaries and releases built in

Factory-fitted with a shunt trip (STL) release and 2 auxiliary switches HQ. No undervoltage release, no ground-fault monitoring, no communication function. The basic switch supplied is 3VA12256EF420AA0. Trip indicator is not present; voltage trigger is present. This variant is configured for line protection with the shunt trip for remote opening — typical for emergency-off or interlocking circuits.

Frequently asked questions

Where can I buy 3VA1225-6EF42-0HC0 and get a price?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the breaking capacity of 3VA1225-6EF42-0HC0 at 415 V?

154 kA at 415 V AC. At 240 V it is 220 kA; at 440 V it is 75.6 kA; at 500 V it is 30 kA; at 690 V it is 17 kA.

Does 3VA1225-6EF42-0HC0 include a shunt trip?

Yes, it is factory-fitted with a shunt trip (STL) release and two auxiliary switches HQ. No undervoltage release or ground-fault monitoring.

MPN
3VA1225-6EF42-0HC0