Skip to main content
Siemens 3VA1225-6GF42-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-6GF42-0KC0 SENTRON MCCB, 250 A, 4-Pole, 220

MPN3VA1225-6GF42-0KC0

Siemens SENTRON 3VA1225-6GF42-0KC0, molded case circuit breaker, 250 A, 4-pole, 220 kA at 240 V, line protection with shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-6GF42-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12256GF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1225-6GF42-0KC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.57 W
3VA1225-6GF42-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1225-6GF42-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-6GF42-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1225-6GF42-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-6GF42-0KC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

The 4-pole configuration covers three-phase plus neutral switching, common in North American 277/480 V panels and European 230/400 V TN systems.

Full 250 A rating holds up to 50 °C ambient; at 55 °C it derates to 243 A, at 65 °C to 230 A, and at 70 °C to 223 A. Max power loss is 57 W.

Auxiliaries and integration

The basic switch supplied is 3VA12256GF420AA0. Dimensions: 140 mm wide, 158 mm high, 70 mm deep — fits standard 4-pole MCCB panel cutouts.

Frequently asked questions

Where can I buy 3VA1225-6GF42-0KC0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What is the breaking capacity of 3VA1225-6GF42-0KC0 at different voltages?

220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V.

Does 3VA1225-6GF42-0KC0 include a shunt trip?

Yes, this variant includes a shunt trip (STL) auxiliary release and two HQ auxiliary switches.

MPN
3VA1225-6GF42-0KC0