Skip to main content
Siemens 3VA1325-7MH32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1325-7MH32-0AH0 SENTRON MCCB, 250 A, 3-Pole

MPN3VA1325-7MH32-0AH0

Siemens SENTRON 3VA1325-7MH32-0AH0, 3-pole molded case circuit breaker, 250 A rated, TM120M thermal-magnetic release, 440 kA breaking capacity at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1325-7MH32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13257MH320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1325-7MH32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C245 A
Current at 60 °C239 A
Current at 65 °C234 A
Current at 70 °C228 A
Switching capacity classC
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V154 kA
Breaking capacity at 690 V17 kA
Power loss, max.30 W
3VA1325-7MH32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1325-7MH32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1325-7MH32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1325-7MH32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1325-7MH32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB does on your line

At 240 V it interrupts 440 kA; at 415 V and 440 V that drops to 242 kA, at 500 V to 154 kA, and at 690 V to 17 kA — so the voltage on your bus decides the fault-clearing headroom you actually have. The thermal derating curve starts at 55 °C: 245 A at 55 °C, 239 A at 60 °C, 234 A at 65 °C, 228 A at 70 °C.

Dimensions are 110 mm deep, 138 mm wide, 248 mm tall — standard SENTRON 3VA footprint for a 250 A frame. Insulation voltage rated at 800 V.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

At 240 V it interrupts 440 kA; at 415 V and 440 V it interrupts 242 kA; at 500 V it interrupts 154 kA; at 690 V it interrupts 17 kA.

Where can I buy 3VA1325-7MH32-0AH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What overcurrent release does this breaker use?

It uses a TM120M thermal-magnetic release.

MPN