Siemens 3VA1332-5EE32-0AA0 SENTRON MCCB, 320 A, 3-Pole

MPN3VA1332-5EE32-0AA0

Siemens SENTRON 3VA1332-5EE32-0AA0, molded case circuit breaker, 3-pole, 320 A rated current, TM220 overcurrent release, 121 kA breaking capacity at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1332-5EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1332-5EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C320 A
Current at 45 °C320 A
Current at 50 °C320 A
Current at 55 °C313 A
Current at 60 °C306 A
Current at 65 °C299 A
Current at 70 °C292 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.80.1 W
3VA1332-5EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1332-5EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1332-5EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1332-5EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1332-5EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

That 320 A holds flat through 50 °C — only starts derating at 55 °C (313 A) down to 292 A at 70 °C, so it handles warm enclosures without a frame size jump. The TM220 overcurrent release combines a thermal fixed-trip element for overloads with a magnetic short-circuit trip, no electronic adjustments to fail or mis-set. Breaking capacity is 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V and 11.9 kA at 690 V. At 240 V it reaches 187 kA.

If your spec calls for shunt trip or aux contacts, you need the -5EE32-0AA0 suffix variant with those options.

Frequently asked questions

How do I get current pricing and availability for 3VA1332-5EE32-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What are the key ratings for 3VA1332-5EE32-0AA0?

Rated 320 A at 40 °C, 3-pole, TM220 overcurrent release, with breaking capacity of 121 kA at 415 V and 187 kA at 240 V.

What is the physical size of 3VA1332-5EE32-0AA0?

Width 138 mm, height 248 mm, depth 110 mm — a standard 3-pole MCCB footprint.