Skip to main content
Siemens 3VA1332-5EF32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1332-5EF32-0BA0 SENTRON MCCB, 320A, 187kA at 240V

MPN3VA1332-5EF32-0BA0

Siemens SENTRON 3VA1332-5EF32-0BA0, 3-pole molded case circuit breaker, 320 A at 40 °C, TM240 overcurrent release, 187 kA breaking capacity at 240 V AC, undervoltage release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1332-5EF32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13325EF320AA0
3VA1332-5EF32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C320 A
Current at 45 °C320 A
Current at 50 °C320 A
Current at 55 °C313 A
Current at 60 °C306 A
Current at 65 °C299 A
Current at 70 °C292 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.82.6 W
3VA1332-5EF32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1332-5EF32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1332-5EF32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1332-5EF32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1332-5EF32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA1332-5EF32-0BA0 is a 3-pole SENTRON molded case circuit breaker rated for 320 A continuous at 40 °C, with a TM240 thermal-magnetic overcurrent release. That 320 A holds flat through 50 °C — no derating needed until you cross 55 °C, where it steps down to 313 A, then 306 A at 60 °C, 299 A at 65 °C, and 292 A at 70 °C. For a panel builder, that means the breaker can sit in a warm enclosure without losing headroom until the ambient climbs past 50 °C. Breaking capacity is the real story here: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V. That 187 kA at 240 V puts it in the high-interrupting class for North American 240 V delta services; the 121 kA at 415 V covers European 400 V grids with plenty of margin for most industrial transformer ratings.

The undervoltage release (UVR) is built in, so if you need a shunt trip for emergency-stop or undervoltage protection, it's already wired.

Frequently asked questions

What is the breaking capacity of 3VA1332-5EF32-0BA0 at 240 V?

187 kA at 240 V AC, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V.

Where can I buy 3VA1332-5EF32-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 3VA1332-5EF32-0BA0 include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as standard, designed for line protection.

MPN
3VA1332-5EF32-0BA0