Skip to main content
Siemens 3VA1332-5EF32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1332-5EF32-0CH0 Circuit Breaker, 55kA @ 415V, 320

MPN3VA1332-5EF32-0CH0

Siemens 3VA1 IEC frame 400 circuit breaker, 3-pole, breaking capacity class M Icu=55kA @ 415V, line protection TM240, ATAM, In=320A, overload protection Ir=224-320A, short-circuit protection Ii=5-10 x In, with undervoltage release 120-127V AC 50/60Hz, 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1332-5EF32-0CH0 is a 3-pole IEC frame 400 molded case circuit breaker with a 55 kA interrupting rating at 415 V (breaking capacity class M). It carries a TM240 thermal-magnetic trip unit rated 320 A continuous, with adjustable overload protection (Ir) from 224 A to 320 A and short-circuit pickup (Ii) adjustable from 5 to 10 times In. This is the line-protection version — ATAM (Adjustable Thermal, Adjustable Magnetic) — meaning you set both the long-time and instantaneous thresholds to match the downstream load, typically a feeder or large motor branch.

The 320 A continuous rating (In) with the TM240 trip means the thermal element is sized for 320 A; the adjustable Ir band lets you dial it down to 224 A if the actual load is lighter, which avoids nuisance tripping on inrush while still protecting the cable. The short-circuit pickup range of 5 to 10 x In (1600 to 3200 A) gives you room to ride through motor starting current without tripping the magnetic element. A typical 320 A feeder feeding a 200 kW motor might see 6-8 x FLA during start; setting Ii at 8 or 9 x In keeps the breaker closed through the start and clears a bolted fault.

Built-in accessories and panel integration

The two auxiliary switches give you status feedback (open/closed) for the PLC or panel indication. All of this is factory-fitted inside the 3VA1 frame, so you do not need to open the breaker cover in the field.

Frequently asked questions

Where can I buy 3VA1332-5EF32-0CH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 3VA1332-5EF32-0CH0?

It is a 3-pole IEC frame 400 circuit breaker with 55 kA interrupting capacity at 415 V, a TM240 thermal-magnetic trip unit rated 320 A continuous, adjustable overload protection from 224 A to 320 A, and short-circuit pickup adjustable from 5 to 10 times In.

What accessories are included with 3VA1332-5EF32-0CH0?

This order code includes an undervoltage release (120-127 V AC, 50/60 Hz) and two auxiliary switches (changeover contacts), all factory-fitted.

MPN
3VA1332-5EF32-0CH0