Skip to main content
Siemens 3VA1332-5EF32-0KJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1332-5EF32-0KJ0 SENTRON MCCB, 320A, 187kA at 240V

MPN3VA1332-5EF32-0KJ0

Siemens SENTRON 3VA1332-5EF32-0KJ0, molded case circuit breaker, 3-pole, rated current 320 A at 40 °C, breaking capacity 187 kA at 240 V AC, thermal-magnetic overcurrent release TM240, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1332-5EF32-0KJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13325EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA1332-5EF32-0KJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C320 A
Current at 45 °C320 A
Current at 50 °C320 A
Current at 55 °C313 A
Current at 60 °C306 A
Current at 65 °C299 A
Current at 70 °C292 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.80.1 W
3VA1332-5EF32-0KJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1332-5EF32-0KJ0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1332-5EF32-0KJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1332-5EF32-0KJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1332-5EF32-0KJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The thermal-magnetic release (TM240) handles overloads and short-circuits; the thermal element responds to sustained overcurrent while the magnetic element clears fast faults. Breaking capacity is 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V — those numbers tell you the maximum fault current the breaker can safely interrupt at each voltage level. It also includes two auxiliary switches plus a separate trip-alarm switch, so you get status feedback for both the breaker position and whether it tripped on fault.

The 3VA1332-5EF32-0KJ0 measures 248 mm high, 138 mm wide, and 110 mm deep — a standard MCCB footprint for 320 A frame size.

Maximum power loss is 80.1 W at rated load. That's dissipated as heat inside the enclosure — factor it into your panel cooling calculation, especially if the breaker is grouped with other heat sources. The rated current derates from 320 A at 40 °C to 292 A at 70 °C; the table shows 320 A holds steady through 50 °C, then drops by roughly 7 A per 5 °C step above that.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

The breaking capacity is 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V. These are the maximum fault currents the breaker can safely interrupt at each voltage level.

What auxiliary switches and releases come with this breaker?

This variant includes two auxiliary switches plus one trip-alarm switch for status feedback. It also has a shunt trip (STL) for remote opening. There is no undervoltage release and no ground-fault monitoring on this suffix.

How do I get pricing and availability for 3VA1332-5EF32-0KJ0?

Submit an RFQ through this listing. We source through our independent distribution network and confirm current pricing and availability at quote time — no stock or price figures are published here.

Will this breaker drop into a panel designed for 3VA2116-5HL32-0AK0?

No — the 3VA1332-5EF32-0KJ0 is a 320 A frame with a TM240 release, while the 3VA2116-5HL32-0AK0 is a different frame size and rating. Physical dimensions and busbar connections differ; you would need to verify the mounting footprint and terminal spacing before substituting.

MPN
3VA1332-5EF32-0KJ0