Siemens 3VA1332-6EF42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1332-6EF42-0AA0-ZD00 Circuit Breaker, 70kA @ 415V

MPN3VA1332-6EF42-0AA0-ZD00

Siemens 3VA1 IEC frame 400, breaking capacity class H, Icu=70kA @ 415V, 4-pole, line protection TM240 ATAM, In=320A, overload Ir=224A..320A, short-circuit Ii=5..10xIn, N conductor unprotected, nut keeper kit for DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

This Siemens 3VA1332-6EF42-0AA0-ZD00 is a 4-pole IEC frame 400 molded case circuit breaker with class H breaking capacity — 70 kA Icu at 415 V. That rating puts it in the high-interrupting tier for industrial distribution panels and transformer secondaries where available fault current runs above 50 kA. The TM240 ATAM trip unit gives adjustable thermal-magnetic protection: overload Ir from 224 A to 320 A, and short-circuit pickup Ii set at 5 to 10 times In (320 A). The N conductor is unprotected — neutral is solidly connected without an overcurrent pole — which is standard for 3-phase 4-wire systems where the neutral carries only unbalanced load.

Mounts on DIN rail or panel-mount via the 3VA1 accessory kit. The 4-pole footprint needs 4 module widths (roughly 72 mm per pole) — verify gland plate clearance before wiring. Line and load lugs accept Cu/Al conductors up to 300 kcmil. The nut keeper kit retains the terminal screws during high-vibration shipping; keep it installed until final torque-down at the panel.

Frequently asked questions

Where can I buy 3VA1332-6EF42-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this breaker?

The 3VA1332-6EF42-0AA0-ZD00 carries an Icu of 70 kA at 415 V AC, which is class H for the IEC frame 400 platform. That means it can safely interrupt fault currents up to 70 kA without damage at that voltage.

What are the overload and short-circuit settings?

Overload protection Ir is adjustable from 224 A to 320 A via the TM240 ATAM thermal-magnetic trip unit. Short-circuit protection Ii is fixed at 5 to 10 times In (320 A), giving a pickup range of 1600 A to 3200 A.

Is the neutral conductor protected on this breaker?

No. The N conductor is unprotected — it is solidly connected without an overcurrent pole. This is typical for 3-phase 4-wire systems where the neutral only carries unbalanced load and does not require overcurrent protection.