Siemens 3VA1340-4GF42-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1340-4GF42-0DH0 SENTRON MCCB, 400 A, 4-Pole

MPN3VA1340-4GF42-0DH0

Siemens SENTRON 3VA1340-4GF42-0DH0, molded case circuit breaker, 400 A, 4-pole, 121 kA interrupting at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1340-4GF42-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13404GF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1340-4GF42-0DH0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C392 A
Current at 60 °C384 A
Current at 65 °C376 A
Current at 70 °C367 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.94.6 W
3VA1340-4GF42-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1340-4GF42-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1340-4GF42-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1340-4GF42-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1340-4GF42-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

400 A MCCB with voltage-graded SCCR

Its interrupting capacity scales with system voltage: 121 kA at 240 V, 75.6 kA at 415 V and 440 V, 52.5 kA at 500 V, and 11.9 kA at 690 V — so the same unit handles both 480 V distribution and 600 V class motor branch circuits, as long as the available fault current at the panelboard stays under the curve.

Auxiliary releases and trip indication

The UVR drops the breaker when control voltage falls below the dropout threshold — standard for emergency-stop chains or undervoltage protection on motor feeders. The trip indicator gives a local visual flag; the alarm switch closes on fault trip, not manual switching, so a PLC or annunciator can distinguish a trip from a planned open.

Active lifecycle — no end-of-life watch needed

The 3VA1340-4GF42-0DH0 carries a current lifecycle status from Siemens. No last-time-buy or successor notice is in effect.

Dimensions are 248 mm high, 184 mm wide, 110 mm deep — a standard 4-pole MCCB footprint for 400 A frames. Maximum power dissipation is 94.6 W; account for that heat in the enclosure thermal calculation, especially if the panel also houses drives or transformers.

MPN
3VA1340-4GF42-0DH0