Skip to main content
Siemens 3VA1340-5EF32-0DJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1340-5EF32-0DJ0 SENTRON MCCB, 400 A, 3-Pole, 187

MPN3VA1340-5EF32-0DJ0

Siemens SENTRON 3VA1340-5EF32-0DJ0, molded case circuit breaker, 3-pole, 400 A at 40 °C, 187 kA interrupting at 240 V, line protection design, undervoltage release, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1340-5EF32-0DJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13405EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA1340-5EF32-0DJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C392 A
Current at 60 °C384 A
Current at 65 °C376 A
Current at 70 °C367 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.94.6 W
3VA1340-5EF32-0DJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1340-5EF32-0DJ0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1340-5EF32-0DJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1340-5EF32-0DJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1340-5EF32-0DJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with high interrupting capacity for line protection

It carries a 187 kA interrupting rating at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V — high enough to handle most fault-current scenarios in industrial mains without cascading upstream breakers.

That matters when the breaker shares an enclosure with other heat sources — plan the thermal budget accordingly. The 3-pole footprint is the same as other SENTRON 3VA frames in this class, so panel cutouts and busbar layouts carry over.

Frequently asked questions

What is the interrupting capacity of 3VA1340-5EF32-0DJ0 at 240 V?

187 kA at 240 V, with 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 11.9 kA at 690 V.

What auxiliary switches come with this breaker?

It includes 2 auxiliary switches plus 1 trip alarm switch, and an undervoltage release.

How do I get pricing and availability for 3VA1340-5EF32-0DJ0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution, with current pricing and availability confirmed at quote time.

MPN
3VA1340-5EF32-0DJ0