Skip to main content
Siemens 3VA1340-6EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1340-6EF32-0DH0 SENTRON MCCB, 400 A, 3-Pole, 220

MPN3VA1340-6EF32-0DH0

Siemens SENTRON 3VA1340-6EF32-0DH0, molded case circuit breaker, line protection, 3-pole, 400 A at 40 °C, 220 kA at 240 V, undervoltage release, 2 aux switches + 1 trip alarm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1340-6EF32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA13406EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1340-6EF32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C392 A
Current at 60 °C384 A
Current at 65 °C376 A
Current at 70 °C367 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V154 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V17 kA
Power loss, max.94.6 W
3VA1340-6EF32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1340-6EF32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1340-6EF32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1340-6EF32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1340-6EF32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA1340-6EF32-0DH0 is a 3-pole molded case circuit breaker rated 400 A at 40 °C, designed for line protection in distribution panels where fault current potential is high. Its interrupting capacity of 220 kA at 240 V and 154 kA at 415 V means it can safely clear severe short-circuit faults without upstream damage — critical for high-capacity transformer secondaries or busway taps. At 690 V the rating drops to 17 kA, so verify the available fault current at the point of installation if using on a 690 V system.

The breaker carries its full 400 A rating up to 50 °C ambient; above that it derates linearly to 376 A at 65 °C and 367 A at 70 °C. Panel builders should account for this when positioning the breaker near other heat sources. Maximum power loss is 94.6 W, which feeds into enclosure thermal calculations for ventilation or forced cooling. Operating temperature range is -25 °C to 70 °C; storage range extends from -40 °C to 80 °C.

Integrated auxiliaries and releases

The UVR ensures the breaker trips if control voltage drops, which is standard for safety circuits and emergency-stop chains.

Frequently asked questions

What is the interrupting capacity of this MCCB at different voltages?

220 kA at 240 V, 154 kA at 415 V and 440 V, 121 kA at 500 V, and 17 kA at 690 V.

Does this breaker include an undervoltage release?

Yes, it includes an undervoltage release (UVR) plus two auxiliary switches and one trip alarm switch.

Where can I buy the 3VA1340-6EF32-0DH0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA1340-6EF32-0DH0