Siemens 3VA1340-7FF42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1340-7FF42-0AA0 MCCB, 400 A, 110 kA @ 415 V

MPN3VA1340-7FF42-0AA0
Active

Siemens 3VA1340-7FF42-0AA0, 3VA1 IEC frame 400, 400 A, 110 kA @ 415 V, 4-pole, TM240 ATAM, line protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

3VA1340-7FF42-0AA0 — Specifications
ParameterValue
Group codeP360
Product group5375
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Series3VA Molded Case Circuit Breakers up to 1600 A, IEC
Export control regulationsAL : N / ECCN : N
Compliance with the substance restrictions according to RoHS directiveSince: 01-11-17

Product details

The Siemens 3VA1340-7FF42-0AA0 is a 4-pole IEC molded case circuit breaker from the 3VA1 series, frame size 400, rated at 400 A continuous. Its headline breaking capacity is 110 kA at 415 V AC — that is the Icu (ultimate short-circuit breaking capacity) in the C breaking class, meaning it can safely interrupt a fault current up to 110,000 A without damage to the breaker itself. For a panel builder or site engineer, that level of SCCR headroom covers most industrial distribution boards fed from a transformer of 1,000 kVA or larger, and it simplifies coordination with downstream devices because the upstream breaker won't limit the let-through energy you need to calculate.

Trip unit and protection settings

The TM240 ATAM thermal-magnetic trip unit gives you an adjustable overload protection band from 280 A to 400 A (Ir), and a short-circuit pickup (Ii) adjustable from 5× to 10× In — so from 2,000 A to 4,000 A. That range lets you dial in the magnetic threshold to ride through motor inrush on a 300 A pump feeder while still clearing a bolted fault fast. The neutral conductor protection is set at 0.5× In, and the breaker ships with a nut keeper kit for secure terminal tightening.

Compliance and regulatory documentation

RoHS compliant since 01-Nov-2017. REACH Article 33 disclosure notes lead (CAS 7439-92-1) above 0.1% w/w in the candidate list. Export control is AL: N / ECCN: N, so no special licensing for standard industrial destinations. The product family is the 3VA Molded Case Circuit Breakers up to 1600 A, IEC, which carries IEC 60947-2 certification — the standard that governs the 110 kA Icu rating and the thermal-magnetic trip performance.

Frequently asked questions

How do I get current pricing and availability for 3VA1340-7FF42-0AA0?

This part is made to order (product class C), so pricing and lead time are confirmed at quote time. Submit an RFQ through our desk and we will source it against current Siemens production schedules and return a firm quote with availability.

What is the breaking capacity of this MCCB?

The ultimate short-circuit breaking capacity (Icu) is 110 kA at 415 V AC, in breaking class C. That is the maximum fault current the breaker can safely interrupt without replacement.

What compliance documentation does Siemens provide for 3VA1340-7FF42-0AA0?

RoHS compliance is declared since 01-Nov-2017. REACH Article 33 disclosure identifies lead above 0.1% w/w. Export controls are AL: N / ECCN: N, no special licensing required.

MPN
3VA1340-7FF42-0AA0