Skip to main content
Siemens 3VA1450-7EF32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1450-7EF32-0AA0 SENTRON MCCB, 500 A, 3-Pole, TM24

MPN3VA1450-7EF32-0AA0
Active

Siemens SENTRON 3VA1450-7EF32-0AA0, molded case circuit breaker, 3-pole, 500 A, TM240 thermal-magnetic release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1450-7EF32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1450-7EF32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C488 A
Current at 60 °C476 A
Current at 65 °C464 A
Current at 70 °C452 A
Switching capacity classC
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V154 kA
Breaking capacity at 690 V17 kA
Power loss, max.122.7 W
3VA1450-7EF32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1450-7EF32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1450-7EF32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1450-7EF32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1450-7EF32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA1450-7EF32-0AA0 is a SENTRON molded case circuit breaker rated 500 A continuous at 40 °C through 50 °C, with a TM240 thermal-magnetic overcurrent release. Three poles, 248 mm tall by 138 mm wide by 110 mm deep. That 138 mm width is about 8 standard DIN modules — plan your gland-plate knockouts and busbar drop accordingly. At full load it dissipates 122.7 W, so in a packed enclosure you'll want a thermal model or at least a vent slot above it.

What the interrupting ratings mean for fault duty

This breaker clears 440 kA at 240 V, 242 kA at 415 V and 440 V, 154 kA at 500 V, and 17 kA at 690 V. Those are the maximum prospective fault currents it can interrupt without welding or rupturing — the 440 kA figure at 240 V covers high-fault industrial services; the 17 kA at 690 V still handles most 690 V distribution. The SCCR of the panel is limited by the lowest-rated device downstream, so this breaker is rarely the weak link.

Thermal derating — where the 500 A holds and where it tapers

At 55 °C it derates to 488 A, at 60 °C to 476 A, at 65 °C to 464 A, and at 70 °C to 452 A.

Frequently asked questions

What is the interrupting rating of this MCCB at 240 V?

440 kA at 240 V. It also clears 242 kA at 415 V and 440 V, 154 kA at 500 V, and 17 kA at 690 V.

What does TM240 mean on this breaker?

TM240 designates the thermal-magnetic overcurrent release — a fixed thermal trip curve paired with a magnetic instantaneous pickup. It's a standard line-protection release, not field-adjustable for electronic trip profiles.

How do I get pricing and availability for this part?

Submit an RFQ through the storefront. The part is sourced to order through independent distribution; current pricing and stock are confirmed at quote time.

MPN
3VA1450-7EF32-0AA0