Skip to main content
Siemens 3VA1463-4EF32-0DF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1463-4EF32-0DF0 SENTRON MCCB, 630A, 3-Pole, 121kA

MPN3VA1463-4EF32-0DF0

Siemens SENTRON 3VA1463-4EF32-0DF0, molded case circuit breaker, 3-pole, 630 A at 40 °C, breaking capacity 121 kA at 240 V AC, line protection design, with undervoltage release.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1463-4EF32-0DF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA14634EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1463-4EF32-0DF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C630 A
Current at 50 °C630 A
Current at 55 °C618 A
Current at 60 °C607 A
Current at 65 °C595 A
Current at 70 °C583 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.195.4 W
3VA1463-4EF32-0DF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1463-4EF32-0DF0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1463-4EF32-0DF0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1463-4EF32-0DF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1463-4EF32-0DF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The continuous current rating is 630 A at 40 °C, and it holds that same 630 A through 50 °C; at 55 °C it derates to 618 A, at 60 °C to 607 A, at 65 °C to 595 A, and at 70 °C to 583 A. The interrupting ratings are what decide whether this breaker clears a fault without upstream damage: 121 kA at 240 V, 75.6 kA at 415 V and 440 V, 52.5 kA at 500 V, and 11.9 kA at 690 V. The 3-pole form factor (138 mm wide, 248 mm tall, 110 mm deep) fits the standard SENTRON 3VA mounting footprint; it carries a built-in undervoltage release (UVR) and one auxiliary switch plus one trip alarm switch, which covers the basic status feedback to a PLC or annunciator.

Frequently asked questions

Where can I buy 3VA1463-4EF32-0DF0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — no stock count or price is published here.

What are the key ratings of 3VA1463-4EF32-0DF0?

Rated 630 A continuous at 40 °C, 3-pole, with breaking capacities of 121 kA at 240 V, 75.6 kA at 415 V, 75.6 kA at 440 V, 52.5 kA at 500 V, and 11.9 kA at 690 V. It includes an undervoltage release and one auxiliary + one trip alarm switch.

What is the depth of 3VA1463-4EF32-0DF0?

The depth is 110 mm (4.33 in). Combined with the 138 mm width and 248 mm height, it fits the standard 3VA mounting footprint.

What compliance documentation does Siemens provide for this MCCB?

As a SENTRON 3VA series MCCB, this part carries the usual Siemens compliance documentation — RoHS, REACH, UL, and IEC declarations are available from Siemens directly. Specific cert numbers are not listed in this record.

MPN
3VA1463-4EF32-0DF0