Skip to main content
Siemens 3VA1463-7EF32-0AA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1463-7EF32-0AA0 MCCB, 630 A, 3-Pole, TM240

MPN3VA1463-7EF32-0AA0
Active

SENTRON 3VA molded case circuit breaker, 3VA1463-7EF32-0AA0, 3-pole, 630 A, TM240 thermal-magnetic release, line protection, 110 x 138 x 248 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1463-7EF32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1463-7EF32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C630 A
Current at 50 °C630 A
Current at 55 °C618 A
Current at 60 °C607 A
Current at 65 °C595 A
Current at 70 °C583 A
Switching capacity classC
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V154 kA
Breaking capacity at 690 V17 kA
Power loss, max.192.9 W
3VA1463-7EF32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1463-7EF32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1463-7EF32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1463-7EF32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1463-7EF32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The SENTRON 3VA1463-7EF32-0AA0 is a 3-pole molded case circuit breaker rated for 630 A continuous current, built for line-protection duty in distribution panels and switchboards. Its TM240 thermal-magnetic release handles overload and short-circuit coordination without an external trip unit.

This breaker delivers 440 kA at 240 V, 242 kA at 415 V and 440 V, 154 kA at 500 V, and 17 kA at 690 V. That spread means it can be specified for high-fault panels at low voltage and still hold coordination at higher system voltages — the 242 kA at 415 V covers most industrial 400 V distribution without needing an upstream current-limiting fuse.

Rated 630 A from 40 °C through 50 °C ambient. Above that, the continuous current drops: 618 A at 55 °C, 607 A at 60 °C, 595 A at 65 °C, and 583 A at 70 °C. Operating ambient spans -25 °C to 70 °C; storage from -40 °C to 80 °C.

Footprint is 138 mm wide by 248 mm tall, with a depth of 110 mm.

Frequently asked questions

What is the interrupting capacity of 3VA1463-7EF32-0AA0 at 415 V?

242 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 440 kA, and at 690 V it drops to 17 kA.

Where can I buy 3VA1463-7EF32-0AA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
3VA1463-7EF32-0AA0