Siemens 3VA1463-7EF32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1463-7EF32-0AJ0 Circuit Breaker, 630A, 110kA @ 41

MPN3VA1463-7EF32-0AJ0

Siemens 3VA1 IEC frame 630 circuit breaker, class C, Icu=110kA @ 415 V, 3-pole, TM240 line protection, In=630A, overload Ir=440…630A, short-circuit Ii=4…8 x In, with 2 AUX SWITCH CHANGEOVER + 1 TRIP ALARM SWITCH CHANGEOVER, nut keeper kit.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1463-7EF32-0AJ0 is an IEC frame 630 molded-case circuit breaker with a class C breaking capacity of 110 kA at 415 V AC. It is a 3-pole unit fitted with a TM240 thermal-magnetic trip unit, rated In=630 A, with overload protection adjustable Ir=440…630 A and short-circuit protection Ii=4…8 x In. The breaker ships with two auxiliary switch changeover contacts and one trip alarm switch changeover contact, plus a nut keeper kit for secure panel mounting.

What the ratings mean for fit

The 110 kA Icu at 415 V is the maximum short-circuit current the breaker can safely interrupt once before needing replacement — that rating places it in the high-breaking-capacity class C tier, suited for main feeders and large distribution boards where fault currents can exceed 50 kA. The TM240 trip unit is thermal-magnetic with a fixed thermal curve (240 A frame) and adjustable magnetic pickup; the Ir range of 440 to 630 A lets you match the continuous load of a transformer or a heavy motor feeder, while the Ii setting of 4 to 8 times In (2,520 to 5,040 A) allows coordination with downstream breakers. The two auxiliary changeover contacts and one trip alarm switch are wired in, so you can signal breaker status and trip events back to a PLC or annunciator panel without adding external relays.

Deployment context

This breaker mounts in a standard panel cutout or on a DIN rail adapter (not included). At 630 A frame size, it requires careful thermal management in the enclosure — the TM240 trip unit dissipates heat proportional to load current, so maintain the manufacturer's recommended clearance for natural convection. The nut keeper kit secures the breaker to the mounting plate, preventing loosening under vibration in industrial environments.

Frequently asked questions

Where can I buy 3VA1463-7EF32-0AJ0 and get a price?

The 3VA1463-7EF32-0AJ0 is sourced to order against an RFQ. Submit a request through the storefront; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this circuit breaker?

The breaking capacity is 110 kA at 415 V AC (class C), meaning it can safely interrupt fault currents up to that level without damage.

What protection settings are available on the 3VA1463-7EF32-0AJ0?

Overload protection Ir is adjustable from 440 to 630 A; short-circuit protection Ii is adjustable from 4 to 8 times In (2,520 to 5,040 A). Both are set via the TM240 thermal-magnetic trip unit.