Skip to main content
Siemens 3VA1510-5EF32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1510-5EF32-0AH0 3VA1 IEC Frame 1000 Breaker, 55kA

MPN3VA1510-5EF32-0AH0

Siemens 3VA1 series, IEC frame 1000, circuit breaker, 3-pole, breaking capacity class M, Icu=55kA @ 415V, TM240 line protection, In=1000A, Ir=700-1000A, Ii=5xIn, with nut keeper kit, 2 auxiliary switches HQ, 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this breaker is and what it does

The Siemens 3VA1510-5EF32-0AH0 is a 3-pole IEC frame 1000 circuit breaker from the 3VA1 series, rated for line protection with a TM240 thermal-magnetic trip unit. Its headline breaking capacity is 55 kA Icu at 415 V (breaking capacity class M), which means it can safely interrupt fault currents up to that level at the panelboard — essential for high-fault installations where upstream coordination demands a robust interrupting rating. The TM240 overload protection is adjustable from 700 A to 1000 A (In=1000 A), and the short-circuit pickup (Ii) is fixed at 5 x In. That fixed magnetic setting suits motor or transformer feeders where the inrush is predictable and a higher instantaneous threshold avoids nuisance tripping on start-up. It ships with a nut keeper kit, two auxiliary switches (HQ), and one trip alarm switch (HQ) pre-installed — so the signaling and alarm contacts are ready for integration into a PLC or annunciator circuit without ordering separate add-on blocks.

Lifecycle and sourcing reality

For a BOM line requiring this exact interrupting rating and trip configuration, the part can be sourced and quoted to order. Availability and current pricing are confirmed at quote time through independent distribution.

Deployment context

This 3VA1 frame breaker mounts on a DIN rail or can be fixed-panel installed — the nut keeper kit secures it in place for high-vibration environments like generator or transformer feeder panels. The auxiliary and alarm switches (HQ) provide status feedback for remote monitoring or safety interlocks.

Frequently asked questions

What is the breaking capacity of this breaker?

The Icu is 55 kA at 415 V, which is the maximum short-circuit current it can safely interrupt at that voltage level.

What are the overload and short-circuit protection settings?

Overload protection (Ir) is adjustable from 700 A to 1000 A via the TM240 thermal-magnetic trip unit; short-circuit pickup (Ii) is fixed at 5 x In (5000 A at the 1000 A rating).

Where can I buy the 3VA1510-5EF32-0AH0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA1510-5EF32-0AH0