Skip to main content
Siemens 3VA1510-5EF32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1510-5EF32-0JA0 SENTRON MCCB, 1000A, 121kA @415V

MPN3VA1510-5EF32-0JA0

Siemens SENTRON 3VA1510-5EF32-0JA0, molded case circuit breaker, 3-pole, 1000 A at 40 °C, 121 kA breaking capacity at 415 V AC, with shunt trip (STL), line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1510-5EF32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA15105EF320AA0
3VA1510-5EF32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C960 A
Current at 60 °C940 A
Current at 65 °C920 A
Current at 70 °C900 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.330 W
3VA1510-5EF32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1510-5EF32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1510-5EF32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1510-5EF32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1510-5EF32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.10 000
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.27 in
Depth (in)4.72 in

Product details

The Siemens 3VA1510-5EF32-0JA0 is a SENTRON molded case circuit breaker rated 1000 A at 40 °C, with a 121 kA breaking capacity at 415 V AC across three poles. The shunt trip (STL) release allows remote trip via a control signal, so it integrates into emergency-stop or undervoltage protection schemes. Rated current holds flat at 1000 A from 40 °C up to 50 °C, then derates to 960 A at 55 °C and 900 A at 70 °C. In a warm enclosure or high-ambient panel, plan for that thermal curve — the breaker doesn't lose headroom until past 50 °C. The 120 mm depth keeps it within typical distribution panel clearances without requiring deep gland plates.

Sourcing and lifecycle — active, no LTB watch needed

That means a replacement shunt trip can be ordered separately if the release fails in service.

Breaking capacity across voltages — where it fits

Breaking capacity scales with system voltage: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, 52.5 kA at 690 V. At 415 V — the most common industrial distribution voltage — 121 kA covers virtually all transformer sizes up to 2500 kVA. At 690 V the 52.5 kA rating still suits heavy motor circuits with high short-circuit current.

Integration — panel fit and wiring notes

Three-pole design with line protection trip curve (TM240 thermal-magnetic release). No undervoltage release fitted, no ground-fault monitoring — those are add-on accessories if the application requires them. The 330 W maximum power loss means ventilation in the enclosure matters; in a sealed cabinet with other high-current devices, account for the heat load. The communication function is absent — this is a stand-alone breaker, not a metering or networked unit.

Frequently asked questions

How do I get pricing and availability for 3VA1510-5EF32-0JA0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and stock levels are confirmed at quote time.

What are the key ratings of this MCCB?

Rated 1000 A at 40 °C, 121 kA breaking capacity at 415 V AC, 3-pole, with shunt trip release (STL). Dimensions 320 x 210 x 120 mm.

Will 3VA1510-5EF32-0JA0 drop into a panel designed for 3VA1110-5EF32-0LA0?

Not without checking the physical footprint and terminal layout. The 3VA1510 frame is a higher-current variant (1000 A vs the 3VA1110 series); panel cutouts, busbar spacing, and lug sizes may differ. Verify the mounting dimensions and connection scheme against the existing panel design before ordering.

MPN
3VA1510-5EF32-0JA0