Skip to main content
Siemens 3VA1580-5EF32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1580-5EF32-0AD0 SENTRON MCCB, 800 A, 187 kA at 24

MPN3VA1580-5EF32-0AD0

Siemens SENTRON 3VA1580-5EF32-0AD0, 3-pole molded case circuit breaker, 800 A at 40 °C, line protection, 187 kA breaking capacity at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1580-5EF32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA15805EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1580-5EF32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C780 A
Current at 60 °C761 A
Current at 65 °C741 A
Current at 70 °C722 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.240 W
3VA1580-5EF32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1580-5EF32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1580-5EF32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1580-5EF32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1580-5EF32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.10 000
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.27 in
Depth (in)4.72 in

Product details

Siemens 3VA1580-5EF32-0AD0 — 800 A SENTRON MCCB, Line Protection, Active Production

Breaking capacity is 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 52.5 kA at 690 V — figures that give selectivity headroom for a main or feeder breaker in a high-fault panel, particularly on the low-voltage side of a 480 V distribution transformer where the available fault current can exceed 100 kA.

Thermal Derating — Continuous Current vs. Ambient

Above 50 °C the breaker must be derated: 780 A at 55 °C, 761 A at 60 °C, 741 A at 65 °C, and 722 A at 70 °C. For a panel with a 55 °C internal ambient — common in a packed switchboard — the breaker is effectively a 780 A device. Account for this during coordination studies; the TM240 overcurrent release is set for the 800 A frame, but the thermal trip curve shifts with ambient.

Configuration and Accessories — What This Order Code Includes

The trip indicator is not fitted, and there is no voltage-trigger function. The design is line protection, meaning the TM240 thermal-magnetic release is matched to cable and busbar protection rather than motor or generator duty.

The breaker is rated for indoor installation in a controlled environment — no IP rating is listed, so it expects enclosure protection. Dimensions are 320 mm height, 210 mm width, 120 mm depth.

Frequently asked questions

Does 3VA1580-5EF32-0AD0 include an undervoltage release or ground-fault monitoring?

No. This variant ships without an undervoltage release, without ground-fault monitoring, and without a shunt trip. It includes three HQ auxiliary switches.

MPN
3VA1580-5EF32-0AD0