Siemens 3VA1580-5EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1580-5EF32-0CC0 Circuit Breaker, 800A, 55kA @ 415

MPN3VA1580-5EF32-0CC0

Siemens 3VA1 IEC frame 1000, 3-pole circuit breaker, breaking capacity class M, Icu=55kA @ 415V, TM240 thermal-magnetic trip, In=800A, overload Ir=560-800A, short-circuit Ii=5 x In, with undervoltage release (UVR) 120-127V AC 50/60Hz, 2 auxiliary switches HQ, nut keeper kit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Product details

What the ratings mean for the panel

The Siemens 3VA1580-5EF32-0CC0 is a 3-pole IEC frame 1000 circuit breaker with a 55 kA ultimate breaking capacity (Icu) at 415 V AC, class M. That 55 kA figure tells you the breaker can safely interrupt a fault current up to that level without self-destruction — critical for selectivity studies in a distribution panel where the upstream transformer can deliver that kind of energy. The TM240 thermal-magnetic trip unit gives you an adjustable overload protection band from 560 A to 800 A (Ir), with a fixed short-circuit pickup at 5 times In (Ii = 5 x 800 A = 4000 A). That fixed magnetic threshold means the breaker is sized for a feeder or large motor branch where you want instantaneous trip above 4000 A, not a lower setting that could nuisance-trip on motor inrush.

Deployment context

This breaker mounts on a standard DIN rail or panel-mount base in a switchboard or motor control center enclosure. The integrated undervoltage release (UVR) at 120-127 V AC 50/60 Hz provides automatic trip on loss of control voltage — common in safety circuits where a downstream contactor or PLC must de-energize the load on power loss. The two HQ auxiliary switches (form C) are wired into the control circuit for status feedback to a PLC or SCADA input module.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA1580-5EF32-0CC0 has an Icu of 55 kA at 415 V AC, class M, on the IEC frame 1000.

What are the overload and short-circuit protection settings?

The TM240 thermal-magnetic trip provides adjustable overload protection (Ir) from 560 A to 800 A, and a fixed short-circuit pickup (Ii) at 5 times In, which is 4000 A for the 800 A rating.

Where can I buy the 3VA1580-5EF32-0CC0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.