Skip to main content
Siemens 3VA1580-5EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1580-5EF32-0DH0 SENTRON MCCB, 800 A, 187 kA

MPN3VA1580-5EF32-0DH0

Siemens SENTRON 3VA1580-5EF32-0DH0, molded case circuit breaker, 3-pole, 800 A at 40 °C, 187 kA breaking capacity at 240 V, line protection design with undervoltage release.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1580-5EF32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA15805EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1580-5EF32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C780 A
Current at 60 °C761 A
Current at 65 °C741 A
Current at 70 °C722 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.242.5 W
3VA1580-5EF32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1580-5EF32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1580-5EF32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1580-5EF32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1580-5EF32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.10 000
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.27 in
Depth (in)4.72 in

Product details

The Siemens 3VA1580-5EF32-0DH0 is a SENTRON molded case circuit breaker rated for line protection — 800 A continuous at 40 °C, with a 187 kA interrupting capacity at 240 V. At 415 V it still holds 121 kA, and at 690 V it's 52.5 kA — so the same unit handles high-fault service entrances and distribution feeders across voltage tiers. The UVR means the breaker drops out if control voltage is lost, which is standard for emergency-stop or safety-shutdown circuits where you want the load isolated on power loss.

At 55 °C it's 780 A; at 60 °C it's 761 A; at 65 °C it's 741 A; at 70 °C it's 722 A. Above that, you size the load or the ventilation around the derated figure.

Dimensions: 210 mm wide, 320 mm tall, 120 mm deep. The 210 mm width is the pole pitch for a 3-pole frame; it's a standard SENTRON 3VA footprint, so if you're swapping into an existing 3VA panel, the bus-bar and lug positions should align without rework.

Frequently asked questions

What are the key ratings for 3VA1580-5EF32-0DH0?

800 A continuous at 40 °C, 187 kA interrupting at 240 V, 121 kA at 415 V, 52.5 kA at 690 V. Three-pole, line protection, with undervoltage release and two auxiliary switches plus trip alarm.

What are the physical dimensions of this MCCB?

210 mm wide, 320 mm tall, 120 mm deep.

How do I get current pricing and availability for 3VA1580-5EF32-0DH0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for this order code.

Does this breaker include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) fitted, plus two auxiliary switches and one trip-alarm switch.

MPN
3VA1580-5EF32-0DH0