Siemens 3VA1580-5EF32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1580-5EF32-0HC0 SENTRON MCCB 800A 3-Pole, 187kA a

MPN3VA1580-5EF32-0HC0

Siemens SENTRON molded case circuit breaker, 3VA1580-5EF32-0HC0, 3-pole, 800 A rated at 40 °C, 187 kA breaking capacity at 240 V, line protection design with shunt trip and 2 auxiliary switches.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1580-5EF32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA15805EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1580-5EF32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C780 A
Current at 60 °C761 A
Current at 65 °C741 A
Current at 70 °C722 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.240 W
3VA1580-5EF32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1580-5EF32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1580-5EF32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1580-5EF32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1580-5EF32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.10 000
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.27 in
Depth (in)4.72 in

Product details

What this 3VA1580-5EF32-0HC0 brings to the panel

The Siemens 3VA1580-5EF32-0HC0 is a SENTRON molded case circuit breaker sized for 800 A continuous at 40 °C, with thermal derating up to 70 °C where it still holds 722 A. That 800 A rating is the same across 40–50 °C, so you get full capacity in most ventilated enclosures without oversizing. Breaking capacity is the headline here: 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 52.5 kA at 690 V. For 415/440 V systems the 121 kA still covers most industrial service entrances. It's a 3-pole breaker with line protection design, meaning it's set up for feeder or main protection in a distribution panel, not motor protection — no overload class or adjustable thermal curve for starting inrush. The shunt trip (STL) on this variant lets you remote-trip from an E-stop or PLC output without a separate undervoltage release.

Auxiliaries and integration

No communication module onboard, so if you need remote monitoring over PROFIBUS or Modbus you'll add the 3VA communication kit separately. Dimensions are 320 mm high, 210 mm wide, 120 mm deep — fits standard SENTRON 3VA fixed-mount or plug-in base.

Frequently asked questions

What auxiliaries are included on 3VA1580-5EF32-0HC0?

It ships with 2 HQ-type auxiliary switches and a shunt trip (STL) release. No undervoltage release and no ground-fault monitoring.

MPN
3VA1580-5EF32-0HC0