Skip to main content
Siemens 3VA2010-4JQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2010-4JQ42-0AA0 MCCB, 100 A, 4-Pole, 121 kA

MPN3VA2010-4JQ42-0AA0

SENTRON 3VA2010-4JQ42-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, 121 kA interrupting at 240 V, line protection design with ground-fault monitoring.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-4JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2010-4JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-4JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2010-4JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-4JQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-4JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-4JQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The SENTRON 3VA2010-4JQ42-0AA0 is a 4-pole molded case circuit breaker rated for 100 A continuous current, sized for line-protection duty in distribution panels. It breaks up to 121 kA at 240 V and 75.6 kA at 415 V — figures that tell you it handles high-fault utility feeds without cascading upstream.

Thermal performance and derating

This breaker holds its full 100 A rating from 40 °C through 70 °C ambient — no derating curve to calculate in a warm enclosure. That is unusual for an MCCB; most lose headroom above 40 °C. The operating range spans -25 °C to 70 °C, storage from -40 °C to 80 °C. Max power loss is 13.5 W, manageable in a sealed panel.

Ground-fault and communication

Ground-fault monitoring uses summation current formation on L + N conductor — it compares line and neutral current to detect leakage. No undervoltage release or voltage-trip module is fitted on this variant.

Panel fit

Dimensions are 181 mm high, 140 mm wide, 86 mm deep. The 4-pole body occupies the same footprint as other SENTRON 3VA frames, so a panel laid out for a 3VA100 or 3VA200 series breaker accepts this unit without re-drilling the mounting plate or re-routing bus bars.

Frequently asked questions

What is the interrupting rating of 3VA2010-4JQ42-0AA0 at 240 V?

121 kA at 240 V, dropping to 75.6 kA at 415 V and 440 V, 52.5 kA at 500 V, and 3 kA at 690 V.

Where can I buy 3VA2010-4JQ42-0AA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

Does this MCCB include ground-fault protection?

Yes, it monitors ground faults via summation current formation on the L + N conductor, comparing line and neutral current to detect leakage.

What compliance documentation is available for 3VA2010-4JQ42-0AA0?

As a SENTRON series MCCB, it carries the standard IEC/UL certifications for molded case circuit breakers. Specific RoHS, REACH, and other compliance declarations are provided with the order documentation.

MPN
3VA2010-4JQ42-0AA0