Siemens SENTRON 3VA2 series molded case circuit breaker, 3VA2010-5HL32-0CA0, 3-pole, 100 A rated continuous current, interrupting rating 187 kA at 240 V, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5HL32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105HL320AA0
3VA2010-5HL32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.16 W
3VA2010-5HL32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-5HL32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5HL32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-5HL32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5HL32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2010-5HL32-0CA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current across a full ambient range from -25 °C to 70 °C — no derating needed up to 70 °C, which is unusual and saves panel space. It carries a 3-pole design with an undervoltage release (UVR) built in, so it drops the load if control power fails, protecting downstream motors or conveyors from a brownout restart.

Interrupting ratings that match your fault level

This MCCB interrupts 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Frequently asked questions

What is the depth of 3VA2010-5HL32-0CA0?

Depth is 86 mm (3.39 in). That's measured from the mounting face to the back of the breaker body, not including handle throw.

What is the width of 3VA2010-5HL32-0CA0?

Width is 105 mm (4.13 in). That's standard for a 3-pole MCCB in this frame size.

Where can I buy 3VA2010-5HL32-0CA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA2010-5HL32-0CA0