Siemens 3VA2010-5HL36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5HL36-0AB0 SENTRON MCCB, 100A, 187kA at 240V

MPN3VA2010-5HL36-0AB0

Siemens SENTRON 3VA2 molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, ETU320 electronic trip unit, IP40 front, 86 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5HL36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-5HL36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2010-5HL36-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5HL36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320

Construction & Connection

3VA2010-5HL36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5HL36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2010-5HL36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5HL36-0AB0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Line protection MCCB with ETU320 — 100 A, 187 kA SCCR

The 3VA2010-5HL36-0AB0: Rated insulation voltage Ui is 800 V, and the breaker carries two HP auxiliary switches as standard. The front face is IP40-rated — suitable for enclosure mounting behind a panel door, not for washdown exposure. Mechanical endurance is rated at 20,000 cycles.

Frequently asked questions

Where can I buy 3VA2010-5HL36-0AB0 and get a price?

This part is available to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time.

What are the key ratings of 3VA2010-5HL36-0AB0?

Rated continuous current Iu is 100 A, interrupting capacity is 187 kA at 240 V (121 kA at 415/440 V, 79 kA at 500 V, 3.4 kA at 690 V). It is a 3-pole molded case circuit breaker with ETU320 electronic trip unit, 800 V rated insulation voltage, and IP40 front protection.

Does 3VA2010-5HL36-0AB0 include a trip indicator or undervoltage release?

No. This variant has no trip indicator, no undervoltage release, no communication function, no phase-failure detection, no ground-fault monitoring, and no auxiliary release. It ships with two HP auxiliary switches only.

MPN