Skip to main content
Siemens 3VA2010-5HL36-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-5HL36-0JL0 MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5HL36-0JL0

Siemens SENTRON 3VA2010-5HL36-0JL0, molded case circuit breaker, 3-pole, 100 A continuous, 187 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5HL36-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2010-5HL36-0JL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5HL36-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5HL36-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5HL36-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2010-5HL36-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5HL36-0JL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2010-5HL36-0JL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed for line protection in distribution panels. Its breaking capacity is 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — so at typical 400 V class supply it clears a 121 kA fault without cascading upstream. The thermal rating holds flat at 100 A from 40 °C through 70 °C ambient, which means no derating curve to chase in a warm enclosure.

Dimensions and panel fit

At 105 mm wide × 181 mm high × 86 mm deep, this MCCB fits standard 3-pole MCCB cutouts in a distribution panel; the depth is shallow enough for a 200 mm deep enclosure with gland plate clearance.

Auxiliary and release options

Factory-fitted with 2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch (HQ type), plus a shunt trip release (STL) for remote tripping — covers status feedback and emergency-off loop integration without adding external relay logic.

Frequently asked questions

What auxiliary switches are included on 3VA2010-5HL36-0JL0?

Two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ type) are factory-installed.

MPN
3VA2010-5HL36-0JL0