Siemens 3VA2010-5HN36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5HN36-0AB0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5HN36-0AB0

Siemens SENTRON 3VA2010-5HN36-0AB0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5HN36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2010-5HN36-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5HN36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5HN36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5HN36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2010-5HN36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5HN36-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2010-5HN36-0AB0 — 100 A MCCB for Line Protection

The Siemens SENTRON 3VA2010-5HN36-0AB0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C, meaning no derating needed in a warm panel — the same 100 A holds at 70 °C as at 40 °C. It is designed for line protection (cable/feeder protection), not motor or generator protection, so the trip curve is fixed for that duty. The interrupting ratings climb steeply: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — that 187 kA figure at 240 V covers high-fault utility feeds or transformer secondaries without needing a current-limiting fuse upstream.

SCCR and Selectivity Planning

For a panel designer coordinating with upstream breakers, the 3VA2010-5HN36-0AB0 delivers 121 kA at 415 V and 75.6 kA at 500 V — these are the numbers to use for IEC 60947-2 short-circuit coordination studies. The 3 kA at 690 V is a steep drop but still covers most 690 V distribution fault levels. The insulation voltage is rated 800 V, so the breaker is electrically suitable for 690 V systems despite the lower interrupting capacity at that voltage. The 13.5 W maximum power loss at rated current matters for thermal management in a sealed enclosure — that heat must be dissipated.

Physical Fit and Accessories

Dimensions: 181 mm high, 105 mm wide, 86 mm deep — this is a standard SENTRON 3VA2 frame size. The breaker ships with 2 auxiliary switches (HP type) pre-installed, and the basic switch assembly is order code 3VA20105HN360AA0. No undervoltage release, no ground-fault monitoring, no communication function, no voltage trip — this is a plain line-protection breaker with auxiliary contacts for status feedback to a PLC or panel lamp. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C.

Frequently asked questions

What is the interrupting capacity of 3VA2010-5HN36-0AB0 at 240 V?

187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Where can I buy 3VA2010-5HN36-0AB0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.