Skip to main content
Siemens 3VA2010-5HN36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5HN36-0CA0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5HN36-0CA0

Siemens SENTRON molded case circuit breaker, 3VA2010-5HN36-0CA0, 100 A, 3-pole, line protection, with undervoltage release, 187 kA at 240 V, 86 x 105 x 181 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5HN36-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105HN360AA0

Ratings

3VA2010-5HN36-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.16 W

Protection & Trip Unit

3VA2010-5HN36-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5HN36-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5HN36-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2010-5HN36-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5HN36-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries — and what it doesn't

The Siemens 3VA2010-5HN36-0CA0 is a 3-pole SENTRON molded case circuit breaker rated for 100 A continuous at 40–70 °C — no derating needed across that band, which simplifies panel scheduling in warm cabinets. Line protection design means it's set up for feeder and distribution duty, not motor branch-circuit protection with an integral overload relay. Breaking capacity hits 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3 kA at 690 V — numbers that cover most industrial service-entrance and sub-distribution fault levels without cascading upstream. Rated insulation voltage is 800 V. The built-in undervoltage release (UVR) trips the breaker when control voltage drops, so it's a fit for emergency-stop or undervoltage-coordinated circuits where you want automatic disconnection on loss of control power.

Panel fit and mounting

Dimensions are 86 mm deep, 105 mm wide, 181 mm tall — fits standard MCCB panel cutouts and busbar centers for a 3-pole frame. No communication function onboard; no ground-fault monitoring module. The breaker is supplied with the basic switch 3VA20105HN360AA0.

Peer comparison — when the panel was specified around 3VA1110-5EF32-0LA0

The 3VA1110-5EF32-0LA0 is a different frame size (likely 160 A or higher) and does not include the undervoltage release. It will not drop into the same panel cutout without rewiring — the mounting hole pattern and busbar centers differ between the 3VA1 and 3VA2 frame families. If your BOM calls for the 3VA2010-5HN36-0CA0, the 3VA1110 is not a mechanical swap.

MPN
3VA2010-5HN36-0CA0