Siemens 3VA2010-5JP32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5JP32-0AH0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5JP32-0AH0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2010-5JP32-0AH0, 100 A continuous, 3-pole, line protection, 187 kA at 240 V, with communication function and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5JP32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105JP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2010-5JP32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5JP32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5JP32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5JP32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2010-5JP32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5JP32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens 3VA2010-5JP32-0AH0 is a SENTRON molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That means the breaker holds its full 100 A rating even in a hot panel or enclosure, which is where most line-protection breakers start to lose headroom. Three-pole construction, designed for line protection (feeders, not motor branch circuits). The interrupting ratings climb to 187 kA at 240 V and 121 kA at 415 V, so it handles high-fault-current utility feeds without cascading upstream — a key spec for main or sub-main breaker positions in industrial switchboards. At 690 V the interrupting capacity drops to 3 kA, which is typical for a 100 A frame at that voltage; verify the available fault current at your secondary side before committing the BOM line.

Panel fit and integration

Footprint: 105 mm wide, 181 mm tall, 86 mm deep. Built-in communication function lets the breaker report status and trip events to a PLC or BMS. Comes with 2 auxiliary switches plus a trip alarm switch (HQ), so you get both status and fault indication without adding external relays.

Lifecycle and sourcing posture

For a critical-spare holding, this is the one to put in the cabinet before it fails. The SENTRON 3VA2 series has a solid field reputation; the 100 A frame with full-temperature rating and high interrupting capacity covers a lot of main-breaker and large-feeder positions across industrial and commercial installs.

MPN