Skip to main content
Siemens 3VA2010-5JP36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5JP36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5JP36-0AA0
Active

Siemens SENTRON 3VA2010-5JP36-0AA0, molded case circuit breaker, 3-pole, 100 A continuous, interrupting capacity 187 kA at 240 V, line protection version with ETU550 electronic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5JP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2010-5JP36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-5JP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2010-5JP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5JP36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-5JP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5JP36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-5JP36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C, with no derating required up to the maximum operating temperature. Its interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — figures that define the available fault current it can safely clear at each voltage level without upstream coordination failure.

Front face protection is IP40, suitable for enclosed panel installations where tools are required to access the breaker; the optional motor drive extension (listed as available) allows remote tripping or reset without opening the door.

Electrical ratings and application context

Frequently asked questions

Will 3VA2010-5JP36-0AA0 drop into a panel specified for 3VA2010-8HL42-0AA0?

Both breakers share the same 3VA2 frame dimensions (105 mm wide, 181 mm high, 86 mm deep), so the physical footprint is identical and no rewiring of the bus or mounting is required. The difference is in the trip unit and accessories — verify the ETU550 release and communication function match your coordination study before swapping.

MPN
3VA2010-5JP36-0AA0