Skip to main content
Siemens 3VA2010-5JP46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5JP46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 187

MPN3VA2010-5JP46-0AA0
Active

Siemens SENTRON 3VA2010-5JP46-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, ETU550 electronic trip unit, 187 kA at 240 V, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5JP46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2010-5JP46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5JP46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5JP46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5JP46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2010-5JP46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5JP46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens 3VA2010-5JP46-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Four poles, with an ETU550 electronic trip unit that supports communication functions for integration into a monitored distribution system.

Interrupting capacity and selectivity

This MCCB delivers 187 kA at 240 V and 121 kA at 415 V, dropping to 75.6 kA at 500 V and 3 kA at 690 V. That 187 kA figure at 240 V gives you headroom for high-fault panels — useful downstream of a large transformer or on a service entrance where available fault current is high. The 121 kA at 415 V covers most industrial 400 V distribution without needing a current-limiting upstream device.

Panel fit and environment

Dimensions are 181 mm high, 140 mm wide, 86 mm deep — a 4-pole MCCB in the SENTRON 3VA frame. Front IP40 protection means it is suited for enclosed panel mounting where the front face is behind a door. The ETU550 trip unit is adjustable and supports communication, so it fits into a monitored distribution scheme with remote trip indication or power metering.

What the ratings mean for fit

The 100 A continuous rating holds at every ambient from 40 °C to 70 °C — no thermal derating curve to calculate for a warm panel. Insulation voltage is rated 800 V, so the breaker is comfortable on 480/277 V or 600 V systems. The ETU550 electronic trip unit gives you adjustable long-time, short-time, instantaneous, and ground-fault protection curves, plus communication for status and metering data.

Frequently asked questions

What is the interrupting capacity of this MCCB?

The 3VA2010-5JP46-0AA0 delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V.

Where can I buy the 3VA2010-5JP46-0AA0?

This part is sourced and quoted to order through independent distribution; availability and current pricing are confirmed at quote time against an RFQ.

What trip unit does the 3VA2010-5JP46-0AA0 use?

It uses the ETU550 electronic trip unit, which supports communication functions for integration into monitored distribution systems.

Does the 3VA2010-5JP46-0AA0 require derating at high ambient temperatures?

No — the 100 A continuous rating holds across the full ambient range from 40 °C to 70 °C without derating.

MPN
3VA2010-5JP46-0AA0