Specifications

3VA2010-5JQ32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2010-5JQ32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-5JQ32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2010-5JQ32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5JQ32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2010-5JQ32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5JQ32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB does on the line

The Siemens SENTRON 3VA2010-5JQ32-0AB0 is a 3-pole molded case circuit breaker rated for line protection, carrying a full-scale value of 100 A across the entire ambient range from 40 °C to 70 °C — no derating curve to chase when the panel gets hot. With a breaking capacity of 187 kA at 240 V and 121 kA at 415 V, it handles high-fault utility feeds without cascading upstream — sized for main or large feeder duty in industrial switchboards. The 86 mm depth and 105 mm width fit standard SENTRON mounting patterns, so a panel builder can swap this into an existing 3VA lineup without redrilling the gland plate.

Panel fit and field notes

Dimensions are 86 mm deep by 105 mm wide by 181 mm tall — a 3-pole MCCB footprint that drops into a SENTRON panelboard or standalone enclosure without surprises. Maximum power loss is 13.5 W, which keeps internal cabinet temperature rise manageable even in a densely packed lineup. Operating temperature range of -25 °C to 70 °C and storage range of -40 °C to 80 °C cover most unheated plant floors and warehouse conditions.

Frequently asked questions

What compliance documentation does this brand provide for 3VA2010-5JQ32-0AB0?

As a SENTRON molded case circuit breaker, it is designed and tested to IEC and UL standards for line protection; specific RoHS/REACH declarations are available from the manufacturer.

MPN
3VA2010-5JQ32-0AB0