Skip to main content
Siemens 3VA2010-5JQ32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5JQ32-0BH0 SENTRON MCCB, 100 A, 3-Pole, Line

MPN3VA2010-5JQ32-0BH0

Siemens SENTRON 3VA2010-5JQ32-0BH0, molded case circuit breaker (MCCB), 3-pole, 100 A rated at 40 °C, line protection design, 187 kA at 240 V, undervoltage release, communication function, active production.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5JQ32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2010-5JQ32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.16 W

Protection & Trip Unit

3VA2010-5JQ32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2010-5JQ32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5JQ32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2010-5JQ32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5JQ32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB does on the line

The Siemens SENTRON 3VA2010-5JQ32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection duty. It carries 100 A continuously at 40 °C ambient — no derating needed up to 70 °C, which makes it a solid pick for warm enclosures or panels near ovens. Breaking capacity hits 187 kA at 240 V, tapering to 121 kA at 415 V and 75.6 kA at 500 V. That SCCR headroom covers most industrial distribution panels without needing a current-limiting fuse upstream. The breaker includes an undervoltage release (UVR) and comes pre-equipped with 2 auxiliary switches plus a trip alarm switch (HQ configuration). Communication function is built in, so it can report status to a PLC or BMS without an add-on module. The trip indicator is mechanical — visible even when the breaker is off, useful for a walk-down.

Panel fit and dimensions

Footprint: 105 mm wide, 181 mm tall, 86 mm deep. Standard MCCB cutout for a 3-pole frame. The 86 mm depth is the body only — allow extra for the UVR coil and auxiliary wiring behind the panel. No DIN-rail mount; this bolts directly to the panel backplate.

Frequently asked questions

What is the depth of this MCCB?

Depth is 86 mm (3.39 in). The width is 105 mm (4.13 in) and height is 181 mm (7.13 in).

MPN
3VA2010-5JQ32-0BH0