Specifications

Identification

3VA2010-5JQ32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2010-5JQ32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5JQ32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2010-5JQ32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5JQ32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2010-5JQ32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5JQ32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens 3VA2010-5JQ32-0JH0 is a 3-pole molded case circuit breaker from the SENTRON family, designed for line protection. It carries a full-scale rating of 100 A and holds that rating flat across the entire ambient range from 40 °C to 70 °C — no derating needed in a warm cabinet. Interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, and still 75.6 kA at 500 V; at 690 V it drops to 3 kA, so for 690 V systems this breaker is a backup device, not the main fault limiter. Built-in communication and a shunt trip release (STL,) allow remote tripping and integration into a monitored distribution scheme. The auxiliary switch configuration — two auxiliary switches plus one trip alarm switch HQ — gives status feedback for both normal and fault states. A voltage trigger and trip indicator are present; no undervoltage release is fitted. Maximum power loss is 13.5 W.

Mounting and integration

Dimensions are 181 mm high, 105 mm wide, 86 mm deep — a standard 3-pole MCCB footprint for panel-mounting on a backplate or DIN rail. The 105 mm width is the same as the 3VA1110 frame family, so a panel laid out for a 3VA1110-5EF32-0AM0 will accept this breaker without drilling new holes or shifting busbars. Verify the busbar lug centers match your existing tap-off; the physical envelope is interchangeable.

Frequently asked questions