Skip to main content
Siemens 3VA2010-5JQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5JQ42-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU5

MPN3VA2010-5JQ42-0AA0
Active

Siemens SENTRON 3VA2010-5JQ42-0AA0, 4-pole molded case circuit breaker, 100 A, ETU560 electronic trip unit, 187 kA at 240 V AC, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2010-5JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-5JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2010-5JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5JQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-5JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5JQ42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens 3VA2010-5JQ42-0AA0 is a 4-pole SENTRON molded case circuit breaker rated for 100 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to 70 °C, which simplifies panel layout in warm enclosures or near other heat sources. Its ETU560 electronic trip unit enables adjustable N-conductor protection (OFF, 20% to 100%) and ground-fault monitoring via summation current formation on L + N — critical for selective coordination on 4-wire systems where neutral protection must match the phase breaker setting. Breaking capacity ranges from 187 kA at 240 V AC down to 3 kA at 690 V AC; at 415 V and 440 V it holds 121 kA, giving headroom for high-fault installations like industrial substations or large motor control centers.

Dimensions of 86 mm depth, 140 mm width, and 181 mm height fit standard 4-pole MCCB panel cutouts — verify gland plate clearance for the 86 mm depth, especially in shallow enclosures. Maximum power loss 13.5 W; operating temperature range -25 °C to 70 °C, storage -40 °C to 80 °C. Communication function integrated.

Frequently asked questions

What is 3VA2010-5JQ42-0AA0's listed depth?

86 mm — check gland plate clearance in shallow enclosures before ordering.

MPN
3VA2010-5JQ42-0AA0