Skip to main content
Siemens 3VA2010-5KP32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0AH0 SENTRON MCCB, 100 A, 3-Pole

MPN3VA2010-5KP32-0AH0

Siemens SENTRON 3VA2010-5KP32-0AH0 molded case circuit breaker, 3-pole, 100 A continuous rating, line protection design, interrupting capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5KP32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2010-5KP32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-5KP32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-5KP32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5KP32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2010-5KP32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5KP32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-5KP32-0AH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, designed for line protection in distribution panels and motor control centers. Its interrupting capacity reaches 187 kA at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — a range that covers most industrial fault-current scenarios below 690 V without needing a current-limiting upstream device.

The 100 A continuous rating holds flat from 40 °C through 70 °C ambient — no derating curve to track in a warm enclosure, which simplifies panel thermal budgeting. At 86 mm deep × 105 mm wide × 181 mm tall, it fits standard MCCB footprints in Siemens SENTRON distribution boards and most third-party enclosures with DIN-rail or screw-mount provisions.

Frequently asked questions

What is the interrupting capacity of this MCCB at different voltages?

The 3VA2010-5KP32-0AH0 delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. This covers most industrial fault-current scenarios below 690 V without requiring an upstream current-limiting device.

Where can I buy 3VA2010-5KP32-0AH0?

This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2010-5KP32-0AH0