Skip to main content
Siemens 3VA2010-5KP32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0BA0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA2010-5KP32-0BA0

Siemens SENTRON 3VA2010-5KP32-0BA0, 3-pole molded case circuit breaker, 100 A rated continuous current, 187 kA breaking capacity at 240 V AC, ETU850 electronic trip unit, undervoltage release, communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5KP32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-5KP32-0AA0
3VA2010-5KP32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.16 W
3VA2010-5KP32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
3VA2010-5KP32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5KP32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-5KP32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5KP32-0BA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

It carries 100 A rated continuous current (Iu) across the 40 °C to 50 °C band, derating to 85 A at 70 °C — so in a warm enclosure you still hold 85 A continuous without nuisance tripping.

The 3VA2010-5KP32-0BA0 delivers 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V. At 415 V, the 121 kA figure covers most industrial service-entrance faults; the drop to 3.4 kA at 690 V means it is not intended for high-voltage motor circuits at that voltage — you would step up to a higher-rated frame for 690 V applications. The ETU850 release coordinates with downstream SENTRON 3VA1 or 3VA2 breakers for selective tripping, keeping a faulted branch isolated while the main stays closed.

The 86 mm depth means it fits flush in most 200 mm deep enclosures without protruding into the gland plate area. Three-pole design with line-side and load-side terminals accepting up to 185 mm² copper or aluminium conductors. The UVR module (3VA9608-0BB11) is factory-installed; no field wiring of the release coil needed. Communication connection uses the integrated RJ45 port on the front face — no separate communication module required.

Frequently asked questions

How do I get current pricing and availability for 3VA2010-5KP32-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity at 240 V?

187 kA at 240 V AC — sufficient for service-entrance duty in most North American 240/120 V panels without series-rating restrictions.

Does this MCCB include an undervoltage release?

Yes, the 3VA2010-5KP32-0BA0 is equipped with an undervoltage release (UVR) — part number 3VA9608-0BB11 — that trips the breaker when control voltage drops below the dropout threshold, commonly used in safety circuits.

What compliance documentation is available for this part?

The SENTRON series carries UL 489, IEC 60947-2, CSA C22.2 No. 5, and CE marking. RoHS and REACH declarations are available from Siemens upon request.

MPN
3VA2010-5KP32-0BA0