Skip to main content
Siemens 3VA2010-5KP32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0BC0 SENTRON MCCB, 100 A, 3-Pole, ETU8

MPN3VA2010-5KP32-0BC0

Siemens SENTRON 3VA2010-5KP32-0BC0, molded case circuit breaker, 3-pole, 100 A rated continuous current, ETU850 electronic trip unit, line protection version, 187 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5KP32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2010-5KP32-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.16 W

Protection & Trip Unit

3VA2010-5KP32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2010-5KP32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5KP32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2010-5KP32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5KP32-0BC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Siemens 3VA2010-5KP32-0BC0 — 100 A SENTRON MCCB with ETU850 trip unit

The Siemens SENTRON 3VA2010-5KP32-0BC0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, built around the ETU850 electronic trip unit. It's a line-protection version from the 3VA2 family, meaning it's set up for feeder and main breaker duty rather than motor branch-circuit protection. The 100 A rating holds flat from 40 °C up to 50 °C, then derates to 85 A at 70 °C — useful to know if this lands in a hot panel or a NEMA 12 enclosure with limited airflow. Breaking capacity is the headline number here: 187 kA at 240 V, 121 kA at 415/440 V, 79 kA at 500 V, and 3.4 kA at 690 V. That 187 kA at 240 V is a high-interrupting rating — this breaker can sit ahead of a transformer or on a high-fault service entrance without needing a current-limiting fuse upstream. The 121 kA at 415 V covers most European industrial distribution panels. At 690 V the rating drops sharply to 3.4 kA, so if you're on a 690 V system this is not your main breaker; it's a downstream feeder where the available fault current is known to be low. Rated insulation voltage is 800 V, so the internal clearances and creepage are sized for 690 V systems with margin. Power dissipation maxes at 16 W — negligible for panel thermal budgeting unless you're packing a dozen of these in a sealed enclosure.

Trip unit, releases, and auxiliaries

The ETU850 is an electronic trip unit with communication and other measurement functions onboard — it can report current draw and event data if the breaker is wired into a higher-level monitoring system. This isn't a basic thermal-magnetic; it's a microprocessor-based unit that gives you adjustable trip curves and remote visibility. The breaker ships with an undervoltage release (UVR) fitted, design code 5KP32. The auxiliary contact configuration is 2 HQ auxiliary switches, and the integrated auxiliary trip is a separate orderable module (3VA9608-0BB11). The supplied basic switch is 3VA2010-5KP32-0AA0. Mechanical endurance is rated at 20,000 operations — typical for a molded case breaker in distribution duty. No phase failure detection on this variant, and no ground fault monitoring module fitted. The trip indicator is not present, so you won't get a local mechanical flag showing the breaker tripped on fault; you'd rely on the aux contact status or the communication channel.

Physical fit and environment

Dimensions: 105 mm wide, 181 mm high, 86 mm deep. That's a standard 3-pole MCCB footprint for the 100 A frame size — it fits the same panel cutout and busbar spacing as other SENTRON 3VA2 breakers. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The 86 mm depth is the overall body depth including the arc chamber; make sure your gland plate or rear-connection cover has clearance for the rear terminals.

Frequently asked questions

What is the breaking capacity of 3VA2010-5KP32-0BC0 at 415 V?

121 kA at 415 V. The same rating applies at 440 V. At 240 V it reaches 187 kA, and at 500 V it's 79 kA.

What trip unit does the 3VA2010-5KP32-0BC0 use?

It uses the ETU850 electronic trip unit, which supports communication and other measurement functions. This is a microprocessor-based unit with adjustable trip curves, not a fixed thermal-magnetic.

Where can I buy the 3VA2010-5KP32-0BC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 3VA2010-5KP32-0BC0 drop into a panel specified for 3VA1010-2ED32-0JA0?

Both are 3-pole SENTRON MCCBs in the 100 A frame class, so the physical footprint (105 mm width, 181 mm height, 86 mm depth) and busbar spacing are the same. The difference is the trip unit and accessories: the 3VA2010-5KP32-0BC0 carries the ETU850 electronic trip with communication, while the 3VA1010-2ED32-0JA0 uses a different trip system. Panel cutout and mounting are compatible, but the wiring for aux contacts and the UVR may differ — verify the terminal assignments before swapping.

MPN
3VA2010-5KP32-0BC0