Siemens 3VA2010-5KP32-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0BL0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5KP32-0BL0

Siemens SENTRON 3VA2010-5KP32-0BL0, molded case circuit breaker, 3-pole, 100 A continuous, 187 kA at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5KP32-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2010-5KP32-0BL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.16 W

Protection & Trip Unit

3VA2010-5KP32-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5KP32-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5KP32-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2010-5KP32-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5KP32-0BL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB brings to the panel

The Siemens SENTRON 3VA2010-5KP32-0BL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed for elevated panel temps. Its interrupting capacity hits 187 kA at 240 V and 121 kA at 415 V, giving you serious fault-energy headroom for high-SCCR industrial feeds. The line-protection design means it's tuned for cable and busbar protection, not motor overload curves. Current-production part (lifecycle stage: current). Includes undervoltage release (UVR) and 2+1+1 auxiliary switch configuration. Communication function onboard.

Sizing and selectivity realities

At 100 A continuous and 187 kA SCCR at 240 V, this breaker sits in the middle of the 3VA2 frame range (adjustable from 150 A minimum to 1 200 A maximum). The 105 mm width (4.13 in) and 86 mm depth (3.39 in) mean it fits standard panel-mount cutouts for SENTRON MCCBs — no special adapters. The 16 W max power loss is modest for this class, so thermal rise in a crowded enclosure stays manageable. Compared to the 3VA1110-5EF32-0AM0, which is a 3-pole 100 A frame with a lower 25 kA interrupting at 415 V, this 3VA2010 carries substantially more fault-current headroom (121 kA at 415 V). If your panel SCCR requirement exceeds 25 kA, this is the correct drop-in — same footprint family, same mounting pattern, but rated for higher-energy distribution points.

What's on board: releases and auxiliaries

The undervoltage release (UVR) is factory-installed — it trips the breaker when control voltage drops below threshold, which is standard for safety circuits that need a loss-of-voltage shutdown. The auxiliary switch block gives you two form-C (changeover) aux contacts, one trip-alarm contact that changes state only on a fault trip, and one electrical alarm contact for remote indication. All wired to the terminal block, no extra assembly required. A communication function is onboard, so the breaker can report status and trip events to a higher-level monitoring system — useful for plant-floor dashboards or predictive maintenance triggers. The basic switch inside is part number 3VA20105KP320AA0, which is the internal mechanism; the complete unit ships as the 3VA2010-5KP32-0BL0 order code.

Environmental and compliance

Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C. That covers most indoor industrial environments and unheated warehouses. The 100 A rating holds across the full operating range — no derating curve to calculate for hot panels.

Frequently asked questions

What auxiliary switches come on this breaker?

Two auxiliary switches (form-C), one trip alarm switch, and one electrical alarm switch — all factory-fitted.

MPN
3VA2010-5KP32-0BL0