Siemens 3VA2010-5KP32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0DH0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA2010-5KP32-0DH0

Siemens SENTRON 3VA series molded case circuit breaker, 3VA2010-5KP32-0DH0, 3-pole, 100 A rated continuous current, 187 kA breaking capacity at 240 V AC, ETU850 electronic trip unit, undervoltage release, auxiliary contacts 2+1 HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5KP32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2010-5KP32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.16 W

Protection & Trip Unit

3VA2010-5KP32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2010-5KP32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5KP32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2010-5KP32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5KP32-0DH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Line protection with ETU850 — what the ratings mean for fit

The Siemens 3VA2010-5KP32-0DH0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for line protection with a continuous current Iu of 100 A and a rated insulation voltage Ui of 800 V. The ETU850 electronic trip unit provides adjustable overload and short-circuit protection curves, making it suitable for feeder or main breaker duty in distribution panels. The 187 kA breaking capacity at 240 V AC means it can safely interrupt very high fault currents without upstream fuses — a key spec for high-fault installations like transformer secondaries or large motor control centers.

Breaking capacity across voltages — the so-what

Breaking capacity drops with voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V. The 121 kA at 415 V is the figure most relevant for European 400 V three-phase panels — it exceeds typical utility fault levels, so the breaker can be applied without series fusing in most commercial and light industrial installations.

Thermal derating and ambient limits

Rated 100 A up to 50 °C ambient; above that it derates linearly to 85 A at 70 °C. Operating range is -25 °C to +70 °C, storage -40 °C to +80 °C. The 16 W maximum power loss matters for panel heat budget — in a sealed enclosure with multiple breakers, that adds up.

Integrated auxiliary and undervoltage release

Comes with 2 auxiliary switches plus 1 trip alarm switch (HQ type) and an undervoltage release (UVR). The UVR trips the breaker when control voltage drops — standard for safety circuits that need to drop out on loss of control power. Communication function is also present, allowing integration into higher-level monitoring systems.

Frequently asked questions

Where can I buy 3VA2010-5KP32-0DH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm availability and current pricing.

What is the breaking capacity of 3VA2010-5KP32-0DH0 at 415 V?

121 kA at 415 V AC.

What is the depth of 3VA2010-5KP32-0DH0?

86 mm.

What is the width of 3VA2010-5KP32-0DH0?

105 mm.

Will 3VA2010-5KP32-0DH0 drop into a panel that was specified around 3VA1010-2ED32-0JA0 without rewiring?

No — the 3VA1010-2ED32-0JA0 is a different frame size and trip unit. The 3VA2010-5KP32-0DH0 has a different footprint and terminal arrangement; a panel designed for the 3VA1010 series would require mechanical and electrical rework.

MPN
3VA2010-5KP32-0DH0