Skip to main content
Siemens 3VA2010-5KP32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-5KP32-0JH0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA2010-5KP32-0JH0

Siemens SENTRON 3VA2010-5KP32-0JH0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, line protection, shunt trip, communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-5KP32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2010-5KP32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-5KP32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2010-5KP32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-5KP32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2010-5KP32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-5KP32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA2010-5KP32-0JH0 is a 3-pole molded case circuit breaker rated for 100 A continuous at 40 °C through 70 °C — no derating needed across that span, which simplifies panel schedules in warm enclosures. Breaking capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — that 187 kA figure at 240 V covers high-fault utility feeds and transformer secondaries where the available fault current is brutal. Line protection design means it's tuned for cable and busbar protection, not motor starting — pair it with a contactor for motor duty.

Panel fit and wiring

Footprint is 105 mm wide by 181 mm tall by 86 mm deep — standard 3-pole MCCB envelope for a 100 A frame; fits existing SENTRON or 3VA cutouts without panel rework. Comes with a shunt trip (STL) and two auxiliary switches plus a trip alarm switch (HQ) — the shunt trip lets a safety PLC or E-stop relay kill the breaker remotely; the alarm switch signals a trip event back to the control system. Communication function onboard — this variant talks to the plant network for power monitoring and remote reset, so it's not a dumb thermal-magnetic; it's a smart breaker in the SENTRON ecosystem.

Frequently asked questions

Does this breaker have a shunt trip or auxiliary contacts?

Yes, it includes a shunt trip (STL) and two auxiliary switches plus a trip alarm switch (HQ).

MPN
3VA2010-5KP32-0JH0