Siemens 3VA2010-5KP32-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-5KP32-0JL0 MCCB, 100 A, 3-Pole, 187

MPN3VA2010-5KP32-0JL0

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA2010-5KP32-0JL0, 3-pole, 100 A rated continuous current (Iu), 187 kA interrupting capacity at 240 V, ETU850 electronic trip unit, line protection version, with communication function and shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-5KP32-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2010-5KP32-0JL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V3.4 kA
Power loss, max.13.5 W
3VA2010-5KP32-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
3VA2010-5KP32-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5KP32-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts4
3VA2010-5KP32-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5KP32-0JL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What the interrupting ratings mean for panel coordination

Its interrupting capacity is the headline figure for panel builders: 187 kA at 240 V, 121 kA at 415 V and at 440 V, 79 kA at 500 V, and 3.4 kA at 690 V.

Thermal derating and continuous current

At 55 °C it drops to 96.25 A, at 60 °C to 92.5 A, at 65 °C to 88.75 A, and at 70 °C to 85 A. If your enclosure runs hot (stacked drives, transformer proximity), size the load or the breaker accordingly; the 70 °C figure is the operating maximum, not a storage limit.

Trip unit, auxiliaries, and communication

The overcurrent release is an ETU850 electronic trip unit — programmable, with LSI protection curves (long-time, short-time, instantaneous). It includes a voltage trigger and a trip indicator. A shunt trip (STL) is integrated as the auxiliary release design. The breaker also carries a communication function and an 'other measurement function' — meaning it can report status and measurements over a bus, though the specific protocol isn't listed in this order code's detail. The basic switch sub-assembly is order code 3VA2010-5KP32-0AA0; the integrated auxiliary trip is 3VA9688-0BL32. No undervoltage release, no phase failure detection, and no ground fault monitoring on this variant.

The width of 105 mm is standard for a 3-pole 100 A frame in the SENTRON 3VA platform; it will occupy the same DIN or screw-mount footprint as other 3VA 3-pole breakers in this frame size.

Maximum power loss is 13.5 W.

Frequently asked questions

What trip unit does 3VA2010-5KP32-0JL0 use?

The ETU850 electronic trip unit, which provides programmable LSI protection (long-time, short-time, instantaneous). It includes a voltage trigger and a trip indicator, plus communication and measurement functions.

Will 3VA2010-5KP32-0JL0 drop into a panel specified for 3VA1010-2ED32-0JA0?

The 3VA2010 is a different frame size and rating than the 3VA1010. The 3VA2010 is a 100 A frame with 187 kA interrupting capacity; the 3VA1010 is a smaller frame. Panel cutouts and bus connections differ between the two frame sizes — they are not drop-in interchangeable without rewiring or adapter kits.

MPN
3VA2010-5KP32-0JL0