3VA2010-5KP32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2010-5KP32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-5KP32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-5KP32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-5KP32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts4
3VA2010-5KP32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-5KP32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-5KP32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed for line protection in industrial and commercial distribution panels. It carries a maximum interrupting rating of 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — the SCCR headroom you need for high-fault utility feeds or transformer secondaries.

Thermal performance and panel fit

This MCCB holds its full 100 A rating across the entire ambient range from 40 °C through 70 °C — no derating curve to calculate for a warm enclosure. The frame measures 86 mm deep by 105 mm wide by 181 mm tall, so it fits standard 3-pole MCCB mounting footprints in switchboards and panelboards. Power dissipation is 13.5 W maximum, manageable for thermal coordination in a multi-breaker lineup.

Auxiliary and communication capability

Factory-fitted with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ configuration), plus a shunt trip (STL) for remote opening. The breaker also carries a communication function onboard — no separate module needed for integration into a BMS or SCADA system. Undervoltage release is not included in this variant.

Frequently asked questions

What is the interrupting capacity of this MCCB at different voltages?

The interrupting rating is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V — sufficient for most high-fault industrial service entrances.

Does this breaker require derating at high ambient temperatures?

No — it holds its full 100 A rating from 40 °C through 70 °C, so no derating calculation is needed for a warm enclosure.

What auxiliary switches and releases come with this breaker?

It ships with 2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch (HQ), and a shunt trip (STL) for remote tripping. Undervoltage release is not included.

Where can I buy 3VA2010-5KP32-0KL0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA2010-5KP32-0KL0