Skip to main content
Siemens 3VA2010-6HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6HL32-0AA0 SENTRON MCCB, 100 A, 242 kA at 24

MPN3VA2010-6HL32-0AA0
Active

Siemens SENTRON 3VA2010-6HL32-0AA0, molded case circuit breaker, 3-pole, 100 A rated continuous current, ETU320 electronic trip unit, 242 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2010-6HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-6HL32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, with an ETU320 electronic trip unit designed for line protection. At 415 V and 440 V it still holds 187 kA, dropping to 121 kA at 500 V and 3 kA at 690 V, so the SCCR headroom is substantial for most industrial distribution.

Panel fit and footprint

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. The 86 mm depth (3.39 in) is shallow enough for shallow backpanels or gland-plate clearance.

Thermal derating and ambient range

The breaker is rated 100 A continuously across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Operating ambient spans -25 °C to 70 °C, storage from -40 °C to 80 °C. That covers most indoor panel environments, including non-conditioned electrical rooms.

Frequently asked questions

Where can I buy 3VA2010-6HL32-0AA0 and how do I get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ to confirm current pricing and availability — no stock count is held on this page.

What is the breaking capacity of 3VA2010-6HL32-0AA0 at 240 V?

242 kA at 240 V AC, which is the highest interrupting rating on this breaker — suitable for high-fault-current service entrance or large distribution panels.

What trip unit does the 3VA2010-6HL32-0AA0 use?

It uses an ETU320 electronic overcurrent release, designed for line protection (not motor or generator protection).

MPN