Skip to main content
Siemens 3VA2010-6HL32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6HL32-0JC0 SENTRON MCCB, 100 A, 3-pole, 242

MPN3VA2010-6HL32-0JC0

Siemens SENTRON 3VA2010-6HL32-0JC0, molded case circuit breaker, 3-pole, 100 A, ETU320 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V, shunt trip STL, 2 HQ auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2010-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2010-6HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4 kA
Power loss, max.13.5 W
3VA2010-6HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2010-6HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2010-6HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6HL32-0JC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this MCCB does — and what the ratings actually mean for your panel

Its 100 A rated continuous current (Iu) holds flat from 40 °C up to 50 °C; above that it derates to 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. That derating curve matters when you stuff this into a crowded enclosure with other heat sources — the nameplate 100 A is only valid if the ambient inside the panel stays at or below 50 °C. The interrupting ratings are where this part earns its keep in high-fault installations: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V. That makes coordination with downstream breakers more precise, especially in selective schemes where you need a deliberate time delay on short-circuit faults.

Auxiliaries and integration — what's built in, what's not

If you need undervoltage protection or ground-fault, you're looking at a different suffix. The unit draws a maximum power loss of 13.5 W, so heat dissipation inside the panel is modest for a 100 A frame. The 86 mm depth is shallow enough to clear most gland plates without a spacer.

Latching endurance is rated for 20,000 operations.

Frequently asked questions

What trip unit does this MCCB use?

It uses the ETU320 electronic trip unit, which provides adjustable long-time, short-time, and instantaneous protection curves for precise coordination with downstream breakers.

Does this MCCB include a shunt trip or undervoltage release?

It includes a shunt trip (STL) for remote tripping and 2 HQ auxiliary switches for status feedback. It does not include an undervoltage release, ground-fault monitoring, or phase-failure detection.

MPN