Siemens 3VA2010-6HL32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2010-6HL32-0KA0 SENTRON MCCB, 100 A, 3-Pole, Shun

MPN3VA2010-6HL32-0KA0

Siemens SENTRON 3VA series molded case circuit breaker, 3VA2010-6HL32-0KA0, 3-pole, 100 A continuous rating, line protection design, with shunt trip (STL) release, 242 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2010-6HL32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA20106HL320AA0
3VA2010-6HL32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W
3VA2010-6HL32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2010-6HL32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2010-6HL32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2010-6HL32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2010-6HL32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2010-6HL32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed for line protection in distribution panels.

This MCCB delivers 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The steep drop at 690 V tells you this breaker is optimized for 240–500 V systems — at 690 V the interrupting rating is much lower, so verify the available fault current at that voltage before specifying.

Thermal Performance and Derating

The continuous current rating holds at 100 A from 40 °C all the way to 70 °C — no derating needed across the full operating temperature range. That simplifies panel layout when the breaker sits near other heat sources.

Shunt Trip Release and Dimensions

The 105 mm width, 181 mm height, and 86 mm depth fit standard panel layouts; 13.5 W maximum power loss is manageable but should be factored into enclosure thermal calculations.

Frequently asked questions

What is the breaking capacity of 3VA2010-6HL32-0KA0 at 240 V?

It is rated for 242 kA at 240 V AC, which covers very high fault-current installations typical in industrial main distribution.

Does this MCCB include a shunt trip release?

Yes, it is equipped with a shunt trip (STL) auxiliary release for remote tripping applications.

Where can I buy 3VA2010-6HL32-0KA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA2010-6HL32-0KA0