Skip to main content
Siemens 3VA2010-6HM42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2010-6HM42-0AA0 MCCB, 100 A, 4-Pole, Line

MPN3VA2010-6HM42-0AA0
Active

Siemens SENTRON molded case circuit breaker, 3VA2010-6HM42-0AA0, 4-pole, 100 A continuous, line protection, 242 kA at 240 V, 187 kA at 415 V, 86 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2010-6HM42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2010-6HM42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.13.5 W

Protection & Trip Unit

3VA2010-6HM42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2010-6HM42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2010-6HM42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2010-6HM42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2010-6HM42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2010-6HM42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed for line protection in distribution panels. Its 242 kA breaking capacity at 240 V and 187 kA at 415 V give it the headroom to clear high-fault currents upstream of a motor control center or switchboard — selectivity coordination stays intact when a downstream device trips first. The ground-fault monitoring version uses summation current formation on L+N conductors, so it catches leakage without a separate core-balance transformer — saves panel space and wiring time.

Thermal performance and derating

The breaker holds its full 100 A rating from 40 °C through 70 °C ambient — no derating curve to chase across the operating range, which simplifies panel thermal calculations in a sealed enclosure. Maximum power loss is 13.5 W for the 100 A 4-pole frame.

Dimensions and panel fit

At 86 mm deep × 140 mm wide × 181 mm high, this MCCB fits standard DIN-rail or direct-mount backpanels — the 140 mm width leaves room for adjacent breakers in a multi-pole lineup.

Frequently asked questions

Does this breaker include ground-fault protection?

Yes, it has a ground-fault monitoring version using summation current formation on L+N conductors.

MPN
3VA2010-6HM42-0AA0